Search results for "Stokes radius"

showing 3 items of 3 documents

Separation of selected peptides by capillary electroendoosmotic chromatography using 3 μm reversed-phase bonded silica and mixed-mode phases

1999

The retention behaviour and selectivity of selected basic, neutral and acidic peptides have been studied by capillary electroendoosmotic chromatography (CEC) with Hypersil C8, C18, Hypersil mixed-mode, and Spherisorb C18/SCX columns, 250 (335) mm x 100 microns, packed with 3 microns particles, and eluted with mobile phases composed of acetonitrile-triethylamine-phosphoric acid (TEAP) at pH 3.0 using a Hewlett-Packard Model HP3DCE capillary electrophoresis system. The selected peptides were desmopressin (D), two analogues (A and B) of desmopressin, oxytocin (O) and carbetocin (C). The peptides eluted either before or after the electroendoosmotic flow (EOF) marker, depending on the concentrat…

ChromatographyChromatographyChemistryElutionOrganic ChemistryAnalytical chemistryGeneral MedicineReversed-phase chromatographyOxytocinSilicon DioxideBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryElectrophoresisCapillary electrophoresisElectrochromatographyIonic strengthDeamino Arginine VasopressinPeptidesChromatography High Pressure LiquidStokes radiusJournal of Chromatography A
researchProduct

Determination of molecular mass, Stokes' radius, frictional coefficient and isomer-type of non-denatured proteins by time-dependent pore gradient gel…

1988

Molecular mass, Stoke's radius, frictional coefficient and isomer-type of non-denatured proteins can be obtained by time-dependent gradient gel electrophoresis by evaluating the resulting data using a two-step mathematical procedure. Provided a histochemical staining procedure is available to locate the position of an enzyme in the gel, crude cell extracts can be used for estimating their molecular size properties. The computation of molecular properties of non-denatured proteins is demonstrated for isozymes of aspartate aminotransferase (EC 2.6.1.1), peroxidase (EC 1.11.1.42) and glucose-6-phosphate dehydrogenase (EC 1.1.1.49) from current-year needles of spruce. The resulting data as well…

Gel electrophoresisShikimate dehydrogenaseChromatographyMolecular massChemistryGlutamate dehydrogenaseClinical BiochemistryReproducibility of ResultsDehydrogenaseEnvironmental pollutionStereoisomerismBiochemistryCatalysisAnalytical ChemistryEnzymesMolecular WeightCalibrationElectrophoresis Polyacrylamide GelPolyacrylamide gel electrophoresisStokes radiusPlant ProteinsElectrophoresis
researchProduct

VORTEX LAYERS IN THE SMALL VISCOSITY LIMIT

2006

In this paper we suppose that the initial datum for the 2D Navier–Stokes equations are of the vortex layer type, in the sense that there is a rapid variation in the tangential component across a curve. The variation occurs through a distance which is of the same order of the square root of the viscosity. Assuming the initial as well the matching (with the outer flow) data analytic, we show that our model equations are well posed. Another necessary assumption is that the radius of curvature of the curve is much larger than the thickness of the layer.

Physicssymbols.namesakeClassical mechanicsHydrodynamic radiusStokes' lawsymbolsRadius of curvatureStokes radiusVortexWaves and Stability in Continuous Media
researchProduct